ABS - American Building Supply, Inc.
Friday, December 15, 2017 -

 


Construction - Specifications: Mineral Core 45-60-90 Minute

Specifications: 3, 5 Ply construction. Meets or exceeds industry standards of WDMA I.S.1-A, WI Section 12, AWI Section 1300. Testing Standards ASTM-E-152, CSFM 43.7, CAN4-S104, NFPA-252, UBC-7-2-97, UL10C
Lay Up Method: Bond and Sand
Maximum Sizes: Width - 4/0 Length - Depends on faces (See faces below for available length)
Thickness: 1-3/4" Only
Stiles: Laminated Composite to wood (Georgia Pacific), Specific to rating* Edge banding veneer or plastic when matching edges required
Rails: Laminated Composite to wood (Georgia Pacific), Specific to rating* Width = 1" Minimum
Core: Gypsum Mineral
Fire Rating: 45-60-90 Minute Rated*
Faces Light Commercial: RN Birch 2 Ply, MDF Back, 1/64" Face Veneer, 8/0 Max length. PS Red Oak 2 Ply, MDF Back, 1/64" Face Veneer, 8/0 Max length. Raw MDF Single Ply, 10/0 Max length Primed MDF Single Ply, 10/0 Max length Embossed Primed MDF Single Ply, 8/0 Max length Embossed Prefinished MDF (Legacy) Single Ply, 8/0 Max length
Faces Architectural: Primed MDO 2 Ply HDF Back, 10/0 Max length Select Species Raw & Prefinished 2 Ply, 1/42" Face, 10/0 Max length Plastic Laminate 2 Ply, 1/50" Face, 10/0 Max length. All laminates meet or exceed NEMA standards.
Adhesive: Type-1 PVA, Interior installation only.
Machining: To Specification
Lites: To Specification
Louvers: To Specification
Temp Rise: 30 Minutes 250 Degrees maximum.
Acoustical Rating: 30 STC Operable (With seal / Pemko S773)
Warranty: Lifetime. See limited warranty for details.
Description Abbreviations: MC-45NP = Mineral Core 45 Minute, Neutral Pressure; MC-45B = Mineral Core 45 Minute, Category B; MC-45A = Mineral Core 45 Minute, Category A; MC-60NP = Mineral Core 60 Minute, Neutral Pressure; MC-60B = Mineral Core 60 Minute, Category B; MC-60A = Mineral Core 60 Minute, Category A; MC-90NP = Mineral Core 90 Minute, Neutral Pressure; MC-90B = Mineral Core 90 Minute, Category B; MC-90A = Mineral Core 90 Minute, Category A
Recommended Use: Architectural, Light Commercial

*See fire door specifications section in catalogue for details on sizes, hardware and construction limitations.

Maximum Sizes
NP
PP Cat-B
PP Cat-A
Single Swing 4/0 X 10/0 4/0 X 9/0 4/0 X 9/0
2 Point Reg. Pair 8/0 X 9/0 8/0 X 9/0 8/0 X 9/0
3 Point Reg. Pair 8/0 X 9/0 8/0 X 9/0 8/0 X 9/0
4 Point Reg. Pair 8/0 X 9/0 8/0 X 9/0 8/0 X 9/0
2 & 4 Point Reg. CVR Pair 8/0 X 9/0 8/0 X 9/0 8/0 X 9/0
2 Point DE Pair 8/0 X 9/0 8/0 X 8/0 8/0 X 8/0
4 Point DE Pair 8/0 X 9/0 8/0 X 8/0 8/0 X 8/0
2 & 4 Point DE CVR Pair N/A 8/0 X 8/0 8/0 X 8/0
Door & Transom Single 4/0 X 10/0 4/0 X 9/0 4/0 X 9/0
Transom Panel 4/0 X 3/4 4/0 X 3/4 4/0 X 3/4
Dutch Door Single 4/0 X 8/0 N/A N/A
Dutch Door Pair N/A N/A N/A



       

.